eneral
parameters |
Model | BJPX-3101 | |
Power Supply | AC220-230V/50Hz,1300VA | ||
Maximum heater output power | 350W/240V | ||
Auxiliary power output | AC220-230V/50Hz,3A | ||
Heater instructions | 0~100% | ||
Temperature control mode | Box temperature mode; infant mode | ||
Box temperature control temperature range | 25~37℃;37~39℃(Leapfrogging Mode) | ||
Skin temperature control temperature range | 34~37℃37~38℃(Leapfrogging Mode) | ||
Sensor temperature display range | 5~65℃ | ||
Warm-up time(ambient temperature is generally + 22 ℃)* |
No more than 40 minutes
|
||
Temperature variability* | No more than 0.5℃ | ||
Temperature uniformity * (the mattress is in a horizontal position) | No more than 0.8℃ | ||
Temperature uniformity * (the mattress is in an inclined position) | No more than 1.0℃ | ||
The difference between average incubator temperature and control temperature | No more than 1.0℃ | ||
Skin temperature sensor accuracy | ±0.2℃ | ||
Humidity
control |
The running time of the water tank is filled with distilled water after | Humidity below 70%RH, at least 24 hours | |
Tank capacity | 1200ml | ||
Humidity display range | 0%RH~99%RH | ||
Humidity control range | 0%~90%(Adjust 1% each time) | ||
Humidity control precision | ±5%RH | ||
Humidity display accuracy
(ambient temperature 25℃, ambient humidity 45%RH + 5% RH) |
±5%RH | ||
Note: in the context of a fairly high ambient humidity, it may not be possible to achieve a
relatively low humidity control |
|||
Oxygen
concentration control |
Oxygen concentration display range | 0%~99% | |
Oxygen concentration display resolution | 1% | ||
Oxygen concentration display accuracy | ±2% O?(The oxygen concentration set value of less than25%)
±3% O?(The oxygen concentration set value of more than 25%) |
||
Oxygen concentration control accuracy | ±4%O?Concentration within the volume | ||
Oxygen concentration setting range | 20%~60%(Adjust 1% each time) | ||
Oxygen sensor service life | Use up to 10,000 hours at 100% oxygen concentration | ||
Ambient
temperature |
The scope of work | +20~+30℃ | |
Transportation and storage | -20~+55℃ | ||
(suggested that the user should not be used in an environment outside the specified range) | |||
Relative humidity | Relative humidity operating range | 30%~75%RH | |
Transportation and storage | No more than 93%RH | ||
Note 🙁 not recommended to be used outside the specified range of environments) | |||
Atmospheric pressure | Transport and storage atmospheric pressure range | 500hPa~1060hPa | |
Working atmospheric pressure range | 800hPa~1060hPa | ||
Applicable Environment Altitude | ≤2000m | ||
Overvoltage category | Ⅱ | ||
Pollution Level |
2 |
||
Air flow rate | Ambient air flow rate | Less than 0.3m/s | |
Other indicators | Ambient noise in constant temperature enclosure | The stable temperature is not more than 45dB (A)
In other states is not more than 50dB (A) Ambient noise is not more than 35dB (A) |
|
Ambient carbon dioxide concentration in constant temperature enclosure | Carbon dioxide gas mixture is injected at the
speed of 750ml/minute right above the mattress about 10cm, the density should be under 0.5%. |
||
Air velocity above the crib mattress | No more than0.35m/s | ||
General alarm |
Power off alarm, fan alarm, sensor alarm, deviation alarm, over temperature alarm, sensor box placement error alarm, water tank placement error alarm, water shortage alarm
|
||
System alarm | ROM alarm, internal alarm system,SRAM alarm, EEPROM alarm, real-time alarm,
communication alarm, ADC alarm, keyboard alarm, battery alarm, LCD display alarm, temperature heating system alarm, humidity heating system alarm |
||
Note: please refer to the contents of the relevant terms and markers. |
Infant Incubator
eneral
parameters |
Model | BJPX-3101 | |
Power Supply | AC220-230V/50Hz,1300VA | ||
Maximum heater output power | 350W/240V | ||
Auxiliary power output | AC220-230V/50Hz,3A | ||
Heater instructions | 0~100% | ||
Temperature control mode | Box temperature mode; infant mode | ||
Box temperature control temperature range | 25~37℃;37~39℃(Leapfrogging Mode) | ||
Skin temperature control temperature range | 34~37℃37~38℃(Leapfrogging Mode) | ||
Sensor temperature display range | 5~65℃ | ||
Warm-up time(ambient temperature is generally + 22 ℃)* |
No more than 40 minutes
|
||
Temperature variability* | No more than 0.5℃ | ||
Temperature uniformity * (the mattress is in a horizontal position) | No more than 0.8℃ | ||
Temperature uniformity * (the mattress is in an inclined position) | No more than 1.0℃ | ||
The difference between average incubator temperature and control temperature | No more than 1.0℃ | ||
Skin temperature sensor accuracy | ±0.2℃ | ||
Humidity
control |
The running time of the water tank is filled with distilled water after | Humidity below 70%RH, at least 24 hours | |
Tank capacity | 1200ml | ||
Humidity display range | 0%RH~99%RH | ||
Humidity control range | 0%~90%(Adjust 1% each time) | ||
Humidity control precision | ±5%RH | ||
Humidity display accuracy
(ambient temperature 25℃, ambient humidity 45%RH + 5% RH) |
±5%RH | ||
Note: in the context of a fairly high ambient humidity, it may not be possible to achieve a
relatively low humidity control |
|||
Oxygen
concentration control |
Oxygen concentration display range | 0%~99% | |
Oxygen concentration display resolution | 1% | ||
Oxygen concentration display accuracy | ±2% O?(The oxygen concentration set value of less than25%)
±3% O?(The oxygen concentration set value of more than 25%) |
||
Oxygen concentration control accuracy | ±4%O?Concentration within the volume | ||
Oxygen concentration setting range | 20%~60%(Adjust 1% each time) | ||
Oxygen sensor service life | Use up to 10,000 hours at 100% oxygen concentration | ||
Ambient
temperature |
The scope of work | +20~+30℃ | |
Transportation and storage | -20~+55℃ | ||
(suggested that the user should not be used in an environment outside the specified range) | |||
Relative humidity | Relative humidity operating range | 30%~75%RH | |
Transportation and storage | No more than 93%RH | ||
Note 🙁 not recommended to be used outside the specified range of environments) | |||
Atmospheric pressure | Transport and storage atmospheric pressure range | 500hPa~1060hPa | |
Working atmospheric pressure range | 800hPa~1060hPa | ||
Applicable Environment Altitude | ≤2000m | ||
Overvoltage category | Ⅱ | ||
Pollution Level |
2 |
||
Air flow rate | Ambient air flow rate | Less than 0.3m/s | |
Other indicators | Ambient noise in constant temperature enclosure | The stable temperature is not more than 45dB (A)
In other states is not more than 50dB (A) Ambient noise is not more than 35dB (A) |
|
Ambient carbon dioxide concentration in constant temperature enclosure | Carbon dioxide gas mixture is injected at the
speed of 750ml/minute right above the mattress about 10cm, the density should be under 0.5%. |
||
Air velocity above the crib mattress | No more than0.35m/s | ||
General alarm |
Power off alarm, fan alarm, sensor alarm, deviation alarm, over temperature alarm, sensor box placement error alarm, water tank placement error alarm, water shortage alarm
|
||
System alarm | ROM alarm, internal alarm system,SRAM alarm, EEPROM alarm, real-time alarm,
communication alarm, ADC alarm, keyboard alarm, battery alarm, LCD display alarm, temperature heating system alarm, humidity heating system alarm |
||
Note: please refer to the contents of the relevant terms and markers. |