Based on 0 reviews
Be the first to review “MT1200 Pro Monitor 12inch Multiparameter” Cancel reply
You must be logged in to post a review.
Related products
-
ETCO2 Respironics Modules, Capnograph Monitor
ETCO2 Mainstream Module
0 out of 5(0)The model CMZ*** is a stable and reliable end-tidal CO2 module with high integrity, developed by CapnoMed Medical Co.Ltd., adopting the non-dispersive infrared technology with two wavebands, the latest microprocessor and digital signal processing technique, and proven concentration algorithm. The module can accurately measure the concentration of the end-tidal CO2, the concentration of the inhaled CO2, respiratory rate, etc. with the CO2 curve diagram in a fast and exact manner. The model BA210 is perfectly applicable to person at different age group, such as baby, child and adult. The sampling flow rate is setup on the upper computer, and the minimum rate can be lowered to 50ml/min. The standard RS232 communication interface can help to quickly integrate the model KH*** with the monitor or other medical systems which need CO2.
Characteristics
- Long-term stability, non-dispersive infrared technology with two wavebands
- Long service life, infrared black body light source with MEMS
- Accurate Results, with built-in temperature, atmospheric pressure, compensation algorithm for the balance gas
- Calibration-free, patented calibration algorithm without the need for calibration
- Low sampling flow rate, the minimum sampling flow rate 50ml/min
- Easy to operate, plug-in measure
- Low cost in usage and storage
Specification
- Respiration rate range: 2~150 breath/minute
- Electric power supply: DC 5V
- Power Consumption: 1.2W
- Usage Environment: 0~40℃, 10~90% RH, without condensation
- Storage Environment: -40~70℃, <90% RH, without condensation
SKU: n/a -
Capnograph Monitor
Emergency Capnograph Device
0 out of 5(0)Technical Specification
Description Compact, battery powered, quantitative capnograph for mainstream CO2 monitoring of adult, pediatric and infant patients.。 Measurements CO2 partial pressure and respiratory rate Measuring principle 2 channel NDIR type gas analyzer,No moving parts Warm up Waveform displayed within 10 seconds, meets specifications within 2 minutes (at 25°C room temperature) Calibration No routine calibration required CO2 Range 0~99 mmHg 0~9.9 %
0~9.9 kPa
CO2 Resolution 1mmHg or 0.1kPa or 0.1% CO2 accuracy 0~40mmHg ±2 mmHg 41~99mmHg ±8% of readings
When RR is above 80 bpm ±12% of readings
Drift of CO2 measurement accuracy
Short drift: Less than 1 mmHg offset in 4 hours Long drift: Meet measurement accuracy requirements within 120 hours
CO2 noise Noise RMS less than 1mmHg at 5% CO2 Total system response time Less than 500ms Recovery time after defibrillator test
Unaffected Respiratory rate 3~150 bpm Respiratory rate accuracy ±1 bpm ETCO2 Calculation Method Peak of the expired CO2 waveform Compensation Built-in atmospheric pressure sensor, automatic pressure compensation Display 128 *128 pixels 1.44 inch TFT color display Dimensions 51 x 43 x 45 mm Weight <65 g (Included batteries) Mechanical robustness Withstands repeated 1 m drops. Meets the shock and vibration requirements for transport of
EN ISO 80601-2-55:2011 clause 201.15.3.5.101.2 and
EN 1789:2007 clause 6.3.4.2 and 6.4.1.
Operating conditions Temperature:0 – 40 ℃ Humidity:<90% (non-condensing)
Atmospheric pressure:50-120 kPa
Storage conditions Temperature:-20 – 70 ℃ Humidity:<95% (non-condensing)
Atmospheric pressure:50-120 kPa
SKU: Model No. : CGB1SA -
ETCO2 Respironics Modules, Capnograph Monitor
ETCO2 Sidestream Module
0 out of 5(0)The model CMY*** is a stable and reliable end-tidal CO2 module with high integrity, developed by CapnoMed Medical Co.,Ltd., adopting the non-dispersive infrared technology with two wavebands, the latest microprocessor and digital signal processing technique, and proven concentration algorithm. The module can accurately measure the concentration of the end-tidal CO2, the concentration of the inhaled CO2, respiratory rate, etc. with the CO2 curve diagram in a fast and exact manner. The model BA220 is perfectly applicable to person at different age group, such as baby, child and adult. The sampling flow rate is setup on the upper computer, and the minimum rate can be lowered to 50ml/min. The standard RS232 communication interface can help to quickly integrate the model KH*** with the monitor or other medical systems which need CO2.Characteristics
- Long-term stability, non-dispersive infrared technology with two wavebands
- Long service life, infrared black body light source with MEMS
- Accurate Results, with built-in temperature, atmospheric pressure, compensation algorithm for the balance gas
- Calibration-free, patented calibration algorithm without the need for calibration
- Low sampling flow rate, the minimum sampling flow rate 50ml/min
- Easy to operate, plug-in measure
- Low cost in usage and storage
Specification
- Respiration rate range: 2~150 breath/minute
- Electric power supply: DC 5V
- Power Consumption: 1.2W
- Usage Environment: 0~40℃, 10~90% RH, without condensation
- Storage Environment: -40~70℃, <90% RH, without condensation